Bosch Addressable Fire Alarm-EN54

Our product range includes a wide range of fah-0420 / fap-0420 smoke detector, fmm-key-form key for manual call point, fnm-420-a-rd sounder indoor, ms 400 base with bosch logo ms 400 b, fpa-5000 address fire panel and flm-420-rlv1 relay interface modules low voltage.

FAH-0420 / FAP-0420 Smoke Detector

FAH-0420 / FAP-0420 Smoke Detector
  • FAH-0420 / FAP-0420 Smoke Detector
  • FAH-0420 / FAP-0420 Smoke Detector
Get Best Quote
Approx. Price: Rs 3,000 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
Alarm Sensor TypePhotoelectric
BrandBosch
MaterialABS
Usage/ApplicationOffice Buildings
Product TypeSmoke detector
ColorWhite
Automation GradeAutomatic
WeightApprox. 80 g / Approx. 135 g
Model NumberFAH-0420 / FAP-0420
Operating Voltage15 to 33 V DC
Permissible Air Speed20 m/s.
Current Consumption0.55 mA
Permissible Storage Temperature-20 deg C to +50 deg C
Permissible Operating Temperature-10 deg C to +50 deg C
Permissible Relative Humidity95% (non-condensing)
Thermal Maximum Part54 deg C / 69 deg C
Dimensions with Base120 x 63.5 mm

The 420 Series Automatic Fire Detectors offer a superb accuracy as well as detection speed and precision. The versions with dual-optical sensor (DO-detectors: FAP-DO420, FAP-DOT420, FAP-DOTC420) are able to detect lightest smoke (TF1 and TF9). These detectors provide all advantages of LSN improved version. The addressing of the detectors can be configured with the integrated turning switches. 


Get best price for Photoelectric ABS FAH-0420 / FAP-0420 Smoke Detector, For Office Buildings
Request
Callback
Yes! I am Interested

FMM-KEY-Form Key for Manual Call Point

FMM-KEY-Form Key for Manual Call Point
  • FMM-KEY-Form Key for Manual Call Point
Get Best Quote
Approx. Price: Rs 145 / PieceGet Latest Price
Product Brochure

Product Details:

BrandBosch
WeightApprox. 224 g
Model NumberFMM-KEY-Form G/H
Operating Voltage24 V DC (16.2 V DC . . . 30 V DC)
Current ConsumptionSpecified by the respective se- curity system
Dimensions135 x 135 x 37 mm / 5.31 x 5.31 x 1.4 in
Housing MaterialPlastic (ASA)
ColorsRed,RAL 3001 Blue,RAL 5005 Yellow,RAL 1003

The FMC-120-DKM Manual Call Points handle manual alarm triggering and are used with conventional technology.

Features:
  • Adjustment of the manual call point after alarm triggering
  • Indicator LED for alarm or for inspection evaluation
  • Second contact with connections for panel control
  • Variants for indoor and outdoor use
Request
Callback
Yes! I am Interested

FNM-420-A-RD Sounder Indoor

FNM-420-A-RD Sounder Indoor
  • FNM-420-A-RD Sounder Indoor
Get Best Quote
Approx. Price: Rs 5,900 / PieceGet Latest Price
Product Brochure

Product Details:

Colorred,similar to RAL 3001 white,similar to RAL 9010
Frequency Range440 Hz up to 2,90 kHz
Model NumberFNM-420-A
Connections0,28 mm2 to 2,5 mm2
MaterialPlastic,ABS
Permissible Operating Temperature-10 deg C to +55 deg C (-25 deg C to +70 deg C)

The indoor sounders are used independently for signaling an alarm directly at the fire location.

Features:
  • The volume of up to 101.3 dB(A)
  • Maximum current consumption of less than 4.05 mA
  • Up to 100 sounders per LSN loop
  • Immediate synchronization
  • 32 different tone types can be selected (incl. DINtone)
Request
Callback
Yes! I am Interested

MS 400 Base with Bosch Logo MS 400 B

MS 400 Base with Bosch Logo MS 400 B
  • MS 400 Base with Bosch Logo MS 400 B
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandBosch
Weight72 g
Model NumberMS 400 Base / MS 400 B
ConnectionsPower supply (0 V,+V) LSN (a1/a2,b1,b2) C-point Shielding
Housing MaterialABS (Novodur)
Housing ColorSimilar to RAL 9010
Dimensions120 x 22.7 mm

The detector head is installed in the Detector BaseMS 400 with MS 400 B.The base is suitable for surface-mounted cable feed as well as for flush-mounted cable feeds, and has separate attachment points for ceiling mount/flush-mounted back boxes. In addition, it fits all standard bore patterns. The Detector Base made of white ABS plastic(Novodur, a color similar to RAL 9010) has a matt finish and seven terminal screws to connect the detector and its features to the fire panel. Contacts connected to the terminals guarantee a secure electric connection when the detector module is installed. Cables up to 2.5 mm2 in diameter can be used. To protect against unauthorized removal, the detector head can be secured with a variable locking.

Installation/Configuration Notes:

Installation information for 400/420 Series Detector Bases
  • The drill holes marked with an "X" may only be used to mount the base to flush-mounted back boxes.
  • Keep shielded auxiliary wire as short as possible, and make sure this is insulated
Request
Callback
Yes! I am Interested

FPA-5000 Address Fire Panel

FPA-5000 Address Fire Panel
  • FPA-5000 Address Fire Panel
Get Best Quote
Approx. Price: Rs 3 Lakh / PieceGet Latest Price
Product Brochure

Product Details:

BrandBOSCH
Depth149 mm
Height638 mm
ColorBlack
Product TypeFire Alarm Control Panel
Model NumberFPA-5000
Width440 mm

Thanks to the modular configuration, the innovative FPA???5000 Modular Fire Panel easily adapts to local circumstances and regulations. Due to the different functional modules, country-specific characteristics are accommodated in the connection just as quickly as the respective alarm handling.

The Fire Panel is Available with Two Different Housings:
  • Housing for mounting directly on the wall
  • Frame installation housings which are fitted to the mounting frame and can be swiveled.

 

With the aid of special mounting kits, the housings can be mounted in 482.6 mm (19") cabinets. All housings can be extended with various additional housings for all conceivable applications.

 

Features:

  • Modular configuration allowing for easy extension
  • Interconnection of up to 32 Panel Controllers, Remote Keypads, and OPC servers
  • Multiple CAN loop connection with high- performance Ethernet backbone and redundancy
  • Installation and auto-detection of functional modules by simply plugging them into the panel rail
  • Connection to BIS Building Integration System via OPC server

 

Functions:

Operation / Processing of Messages:

The operation and the processing of all messages are easy and intuitive thanks to the ergonomically- designed control panel with its TFT touch???screen offering a menu-driven handling and multi-color display. To that end, there are permanently located keys on the right, bottom, and upper edge of the display as well as variably located virtual keys in the touch-screen area.

 

Modular Structure of the FPA???5000 Modular Fire Panel:

Due to its modular structure, the FPA???5000 Modular Fire Panel provides complete flexibility and thus customized solutions for any application.

 

Modules:

The functional modules are autonomous, encapsulated units that can be inserted into any control panel slot using "plug-and-play" technology. Thus, the power supply and the data traffic to the control panel are indicated automatically without any additional settings. The module is automatically identified by the control panel and functions in the default operating.


Wiring to external components is performed using compact connector/screw terminals. After a replacement, only the connectors need to be reinserted; extensive rewiring is no longer required. defined as network node or local node. Within a group, only panel conditions of the same group can be displayed. Regardless of the groups, network nodes allow for the display and handling of all panel conditions. Local nodes display the conditions of the related panel.

 

Detection Points:

The Address Cards activate detection points. The FPA???5000 governs up to 4096 detection points. Each element and input which, after the programming, is able to set off an alarm requires a detection point. Inputs are considered as detection points if they are programmed accordingly in the FSP???5000???RPS Programming Software.

 

The provided options according to EN 54???2:1997/
A1:2006 include:

  • Output to fire alarm devices
  • Connection conditions for the regional authorities and institutions (police, fire service) must be maintained.
  • It is preferable to use the loop formation owing to the greater security of loop lines compared with stub lines.
  • It is possible to combine LSN interface modules and LSN detectors on one loop or stub line.
  • For a mixed connection of LSN classic elements and LSN improved elements, a maximum of 127 elements are permitted.
  • Existing conventional detectors can be connected to a CZM 0004 A module. A CZM 0004 A module provides four DC primary lines (zones).
Request
Callback
Yes! I am Interested

FLM-420-RLV1 Relay Interface Modules Low Voltage

FLM-420-RLV1 Relay Interface Modules Low Voltage
  • FLM-420-RLV1 Relay Interface Modules Low Voltage
Get Best Quote
Approx. Price: Rs 3,800 / PieceGet Latest Price
Product Brochure

Product Details:

Model NumberFLM-420-RLV
ColorSignal white,RAL 9003
BrandBosch
Permitted Operating Temperature-20 deg C to +55 deg C
Protection ClassIP 30
DimensionsApprox. 50 mm x 22 mm
LSN Input Voltage15 V DC to 33 V DC (min. to max.)
Permitted Storage Temperature-25 deg C to +80 deg C
Permitted Relative Humidity96% (non-condensing)
Max Current Consumption from LSN1.75 mA
RelayNormally closed,common and normally open contact (NC/COM/NO)
WeightApprox. 35 g / 130 g
Housing MaterialABS/PC Blend

The FLM¿¿¿420¿¿¿RLV1 Relay Interface Modules Low Voltage feature a changeover contact relay for providing a potential-free output contact. They are 2¿¿¿wire LSN elements. When connected to the fire panels FPA¿¿¿5000 and FPA¿¿¿1200, the interface module offers the enhanced functionality of LSN improved technology.

Features:
  • Maximum switching current of 5 A/30 V DC (type DINrail), 1 A/30 V DC (type in-built), 0.5 A/42.4 V AC(both variants)
  • Low current consumption
  • Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
Request
Callback
Yes! I am Interested

FLM-420-O1I1 Output-Input Interface Modules

FLM-420-O1I1 Output-Input Interface Modules
  • FLM-420-O1I1 Output-Input Interface Modules
Get Best Quote
Approx. Price: Rs 4,200 / PieceGet Latest Price
Product Brochure

Product Details:

DimensionsApprox. 50 mm x 22 mm
BrandBosch
WeightApprox. 35 g / 170 g
Address Setting8 DIP switches
Housing ColorSignal white,RAL 9003
Connections14 screw terminals
Housing MaterialABS/PC blend
Model NumberFLM-420-O1I
LSN Input Voltage15 V DC to 33 V DC
Permissible wire Diameter0.6 mm 2 to 2.0 mm 2
Max Current Consumption from LSN1.9 mA

The FLM¿¿¿420¿¿¿O1I1 Output-input Interface Modules are fitted with one output to control external devices and with one monitored input. They are 2¿¿¿wire LSN elements for connection to the fire panels FPA¿¿¿5000 and FPA¿¿¿1200 and offer the enhanced functionality of LSN improved technology.

Features:
  • Semi-conductor output electrically isolated from LSNloop and short-circuit proof
  • Max. switchable current per output 700 mA
  • Individually selectable input monitoring functions(EOL or contact)
  • Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
Request
Callback
Yes! I am Interested

FAA-420-RI-ROW Response Indicator

FAA-420-RI-ROW Response Indicator
  • FAA-420-RI-ROW Response Indicator
Get Best Quote
Approx. Price: Rs 650 / PieceGet Latest Price
Product Brochure

Product Details:

BrandBosch
Dimensions85 x 85 x 29 mm
Operating Temperature-20 deg C to +65 deg C
Current Consumption3 mA
Model NoFAA-420-RI-ROW
Permissible Wire Gauge0.45 mm - 1.4 mm
Protection ClassIP 40
Weight45 g
Permissible Relative Humidity95% (non-condensing)

The remote indicator is used when the automatic detector is installed in a place hidden or not visible, like in closed rooms, false ceilings or walls. It is recommended to mount the remote indicator in corridors or access pathways of the corresponding building sections or rooms.

Features:
  • 360° view, for both wall mount and ceiling mount
  • Easy cabling thanks to cable ties bracket and all-direction knock-out holes
  • Long life and robust construction housing
  • Efficient LED

Request
Callback
Yes! I am Interested

FAP-425-OT Optical Thermal without Rotary Switches

FAP-425-OT Optical Thermal without Rotary Switches
  • FAP-425-OT Optical Thermal without Rotary Switches
Get Best Quote
Approx. Price: Rs 3,800 / PieceGet Latest Price
Product Brochure

Product Details:

BrandBosch
Model No.FAP-425-OT
Dimensions With base120 x 63.5 mm
MaterialPlastic,ABS (Novodur)
ColorWhite,similar to RAL 9010,matt finish
WeightApprox. 75 g / Approx. 115 g
Operating Voltage15 V DC to 33 V DC
Current Consumption0.55 mA

AVENAR detector FAP-425-OT is a new range of automatic fire detectors featuring a superb accuracy and swiftness detection. The versions with two optical sensors(dual???optical) are able to detect the lightest smoke. The range includes versions with rotaries, manually and automatically addressable, and versions without rotaries for automatic address setting.

Features:
  • Highly reliable and accurate thanks to IntelligentSignal Processing (ISP)
  • Earliest detection of lightest smoke with dual-optical versions (Dual-Ray technology)
  • Monitors environment for electromagnetic influence for fast root-cause analysis
  • Automatic and manual addressing
Request
Callback
Yes! I am Interested

FAH-425-T-R Heat with Rotary-Switches

FAH-425-T-R Heat with Rotary-Switches
  • FAH-425-T-R Heat with Rotary-Switches
Get Best Quote
Approx. Price: Rs 2,750 / PieceGet Latest Price
Product Brochure

Product Details:

BrandBosch
Min Permitted Storage Temerature-25 deg C
Max Permitted Storage Temerature+80 deg C
Permitted Relative Humidity95 % (non condensing)
Operating Voltage15 V DC to 33 V DC
Current Consumption0.55 mA
Max Iinstallation Height7.5 m
Min Permitted Operating Temperature-20 deg C
Weight75 g

AVENAR detector 4000 combines standard detection procedures such as scattered light and temperature measurement with gas measuring technology at the highest configuration level. This method uses intelligent evaluation electronics (Intelligent Signal Processing - ISP) to evaluate the signals from the smoke, thermal and gas sensor. Thus, immunity against false alarms is increased significantly and detection time is reduced in comparison to the fire detectors available on the market today. Thanks to the combined information collected by the multi-sensor detectors, they can be used in environments where simple smoke detectors cannot be employed. AVENAR detector 4000 is suitable for surface and flush mounting and includes separate mounting points for dropped ceiling and concealed sockets. AVENAR detector 4000 is available in different versions of single-sensor and multi-sensor detectors.
Request
Callback
Yes! I am Interested

FMR-5000-C-13 Remote Keypad

FMR-5000-C-13 Remote Keypad
  • FMR-5000-C-13 Remote Keypad
Get Best Quote
Approx. Price: Rs 62,000 / PieceGet Latest Price
Product Brochure

Product Details:

Dimensions280 mm x 340 mm x 87 mm
LCD Display86 mm x 116 mm
Housing Material and ColorABS plastic,light gray (similar RAL 7035)
Remote Keypad12 V DC to 30 V DC
Max Resistance18
Max Cable Length1000 m
Display Element14.5 cm (5.7") multi-color TFT display with 320 x 240 pixels
Weightca. 3 kg

Features:
  • Convenient remote operation of fire panel identical to Panel Controller
  • Multi-color display
  • 12 LEDs displaying the operating status of the system
  • Surface and flush mounting
Request
Callback
Yes! I am Interested

Fmc-210-Dm-G-r Mcp Lsn Indoor Red

Fmc-210-Dm-G-r Mcp Lsn Indoor Red
  • Fmc-210-Dm-G-r Mcp Lsn Indoor Red
Get Best Quote
Approx. Price: Rs 4,000 / PieceGet Latest Price
Product Brochure

Product Details:

Operating Temperature-25 to 70 deg C
BrandBosch
Housing MaterialPlastic ASA
Degree of ProtectionIP 54
Dimensions135 x 135 x 40mm
WeightApprox. 235 g
Model NumberFMC-210-DM
Operating Voltage24 (15 to 33) VDC
Current Consumption0.4mA

The FMC-210-DM Double-action Call Points are used for manual triggering and can be used in the LocalSecurityNetwork LSN and LSN improved. Form manual Call Points are designed for outdoor deployment, form G Manual Call Points are designed for indoor deployment.

Features:
  • Adjustment after alarm triggeringuIndividual identification thanks to automatic or manual detector addressing
  • Indicator LED for alarm or for inspection evaluation
  • Query routines with evaluation and multiple transmission
  • Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
Request
Callback
Yes! I am Interested
X

Product Videos

Watch More Videos

Explore More Products

View All Products




Reach Us
Aditya Agrawal (Partner)
Nadvin Techlabs
No. 60, Park City
Raigarh - 496001, Chhattisgarh, India


Call Us


Send E-mail