Bosch Addressable Fire Alarm-UL

We are a leading Authorized Wholesale Dealer of avenar panel 2000, fap-440-d dual ray detectors, fap-440-t analog photo and heat detector, fpa-1000-v2 addressable fire panel-ul, fah-440 analog heat detector and fad-325 analog duct detector from Raigarh, India.

AVENAR Panel 2000

AVENAR Panel 2000
  • AVENAR Panel 2000
  • AVENAR Panel 2000
  • AVENAR Panel 2000
  • AVENAR Panel 2000
  • AVENAR Panel 2000
  • AVENAR Panel 2000
  • AVENAR Panel 2000
  • AVENAR Panel 2000
  • AVENAR Panel 2000
  • AVENAR Panel 2000
  • AVENAR Panel 2000
Get Best Quote
Approx. Price: Rs 1.5 Lakh / PieceGet Latest Price
Product Brochure

Product Details:

Product TypeCompact modular fire panel
Usage/ApplicationAll Use
BrandBOSCH
Zones2 Loop
Model Name/NumberAVENAR panel 2000
Voltage230V
MaterialControl Pannel
ColorRed, Black

The fire panel allows mixed operation of analog addressable and conventional technology. It supports connecting periphery in either stub or loop topologies. Analog addressable fire detectors, manual call points, signaling devices, inputs and outputs are identified and managed by the fire panel as single elements. As required by the building structure the peripherals are grouped software wise in logical zones. The compact modular fire panel comes as a kit in a housing. The functional modules can be plugged onto the rail inside the housing. The rail provides power and internal communication to the functional modules. A wide range of functional modules is available providing different connections and functions: addressable loops, conventional zones, inputs and outputs as well as interfaces to various devices. The fire alarm panel can be equipped with six functional modules of which a maximum of four can be analog addressable loop modules. This makes the fire panel suitable for small to medium size applications. The fire panel is available with two different types of housings: • Wall mount housing
• Frame mount housing
 The slim wall mount housings are for mounting directly to the wall. Frame mount housings require an additional frame between the housing and the wall.
Request
Callback


Additional Information:

  • Item Code: AVENAR-panel-2000
Yes! I am Interested

FAP-440-D Dual Ray Detectors

FAP-440-D Dual Ray Detectors
  • FAP-440-D Dual Ray Detectors
  • FAP-440-D Dual Ray Detectors
  • FAP-440-D Dual Ray Detectors
  • FAP-440-D Dual Ray Detectors
  • FAP-440-D Dual Ray Detectors
  • FAP-440-D Dual Ray Detectors
  • FAP-440-D Dual Ray Detectors
Get Best Quote
Approx. Price: Rs 4,500 / PieceGet Latest Price
Product Brochure

Product Details:

Temperature+32 deg F to +100 deg F (0 deg C to +38 deg C)
Model NumberFAP-440-D
Operating Voltage24 V DC to 41 V DC
BrandBosch
Alarm5 mA
Standby0.17 mA
Detector Dimensions4.4 in. x 2.0 in. (11.2 cm x 5.1 cm)
Housing MaterialCYCOLOY/ABS
Protection CategoryIP42
Sensor Airflow4000 ft/min (20 m/s) maximum

The FAP 440 Dual Ray Detectors are open-area smoke detectors of which some models are enhanced with heat or heat and CO sensors. These detectors work with the FPA 1000 Analog Addressable Fire Panels. Use the detector with the FAA 440 bases to provide general life safety and property protection.

Frequency:
  • Dual Ray Technology provides better particle size differentiation resulting in fewer false alarms
  • The smoke threshold is adjustable and automatically compensated
  • Rotary switch addressing
  • Flexible work modes determined by the control panel
  • Selectable base locking mechanism prevents malicious removal of the detector
Request
Callback
Yes! I am Interested

FAP-440-T Analog Photo and Heat Detector

FAP-440-T Analog Photo and Heat Detector
  • FAP-440-T Analog Photo and Heat Detector
  • FAP-440-T Analog Photo and Heat Detector
  • FAP-440-T Analog Photo and Heat Detector
  • FAP-440-T Analog Photo and Heat Detector
  • FAP-440-T Analog Photo and Heat Detector
  • FAP-440-T Analog Photo and Heat Detector
  • FAP-440-T Analog Photo and Heat Detector
Get Best Quote
Approx. Price: Rs 2,800 / PieceGet Latest Price
Product Brochure

Product Details:

BrandBosch
Model NumberFAP-440-T
Operating Voltage24 VDC to 41 VDC
Dimensions4.4 in. x 2.0 in. (11.2 cm x 5.1 cm)
Airflow4000 ft/min (20 m/s) maximum
Alarm5 mA
Relative Humidity95% (non-condensing)
Installation Temperature+32 deg F to +100 deg F (0 deg C to +38 deg C)

Analog Multisensor Detector Photo/Heat. The FAP-440-T Analog Detectors are open-area smoke detectors of which some models are enhanced with heat or heat and CO sensors. These detectors work with the FPA-1000 Analog Addressable Fire Panels. Use these detectors with the FAA-440-T bases to provide general life safety and property protection.

 

Features:

  • The smoke threshold is adjustable and automatically compensated
  • Rotary switch addressing
  • Flexible work modes determined by the control panel
  • Selectable base locking mechanism prevents malicious removal of the detector
  • Multi-criteria or multi-sensor technology reduces false alarms
Request
Callback
Yes! I am Interested

FPA-1000-V2 Addressable Fire Panel-UL

FPA-1000-V2 Addressable Fire Panel-UL
  • FPA-1000-V2 Addressable Fire Panel-UL
Get Best Quote
Approx. Price: Rs 75,000 / PieceGet Latest Price
Product Brochure

Product Details:

Operating Temperature+32 deg F to +120 deg F (0 deg C to +49 deg C)
Loop Capacity2
BrandBosch
Protection ClassIP 30
Weight18.1 lb (8.32 kg)
Voltage120 VAC,60 Hz or 240 VAC,50 Hz
Batteries Voltage2 x 12 VDC in series
Dimensions14.5 in. x 4.3 in. x 22.7 in.
Relative HumidityUp to 95%,non-condensing
Current120 VAC 2 A maximum,240 VAC 1 A maximum
Model NumberFPA-1000-V2
Storage Temperature+14 deg F to +131 deg F (-10 deg C to +55 deg C)

The FPA???1000???UL Analog Addressable Fire Panel is an advanced analogue control panel for small to medium facilities in commercial or public building applications. The FPA???1000???UL combines complete built-in FireAlarm Control Panel (FACP) equipment such as Notification Appliance Circuits (NACs), Signaling Line Circuits (SLCs), relays, power supply, Digital Alarm Communicator Transmitter (DACT), and Ethernet connection with expandability using the option bus or plug???inboards. The two integrated NICs can be expanded with remote addressable NAC power boosters and programmed with specific activation patterns. The standard control panel includes one SLC that supports 254 addressable points (254 analogue detectors or modules, or 127 analogue sounder bases in combination with a suitable detector). The control panel is easily expandable with the FPE???1000???SLC Signaling Line Circuit Plug-in Module, doubling the address points to508.

Features:
  • Support for up to 508 points on two analogue addressable loops
  • Built???in Ethernet connector for web???browser based programming and ConettixIP Alarm-over-IP communication
  • Carbon Monoxide Detector (gas) support meetsNFPA 720 (2009) requirements for visual and audible annunciation
  • Auto???Learn mode for easy provisioning
  • On???line help and off???line programming capability provides simple configuration and service
Request
Callback
Yes! I am Interested

FAH-440 Analog Heat Detector

FAH-440 Analog Heat Detector
  • FAH-440 Analog Heat Detector
Get Best Quote
Approx. Price: Rs 2,400 / PieceGet Latest Price
Product Brochure

Product Details:

Model NumberFAH-440
Operating Voltage24 VDC to 41 VDC
BrandBosch
Dimensions4.4 in. x 2.0 in. (11.2 cm x 5.1 cm)
Sensitivity+135 deg F to +194 deg F (+57 deg C to +90 deg C), programmable + RoR
Alarm5 mA
Airflow4000 ft/min (20 m/s) maximum
Standby0.17 mA
Protection CategoryIP42
Relative Humidity95%
Storage Temperature-13 deg F to +176 deg F (-25 deg C to +80 deg C)
Housing MaterialCYCOLOY/ABS

The FAH¿¿¿440 Analog Heat Detector is an open-area fire detector that works with the FPA¿¿¿1000 AnalogAddressable Fire Panels. Use it with the FAA¿¿¿440family of bases in indoor dry environments with high ambient temperatures where smoke detectors might not be suitable because of steam or fumes; such as kitchens, boiler rooms, or drying rooms.

Features:
  • A selectable Fixed Temperature threshold
  • Rate-of-Rise feature can be switched on or off
  • Selectable base locking mechanism prevents malicious removal of the detector
Request
Callback
Yes! I am Interested

FAD-325 Analog Duct Detector

FAD-325 Analog Duct Detector
  • FAD-325 Analog Duct Detector
Get Best Quote
Approx. Price: Rs 10,200 / PieceGet Latest Price
Product Brochure

Product Details:

BrandBosch
Model/TypeFAD-325
VoltageDCP powered loop; requires 24 VDC power supply
Weight3 lb (1.36 kg)
Duct Air Velocity300 ft/min to 4000 ft/min (1.5 m/ s to 20.3 m/s)
Relative Humidity10 % to 85 % non-condensing
Dimensions9 in. x 7.3 in. x 2.3 in. (22.9 cm x 18.5 cm x 5.84 cm)
Remote Indication OptionsAlarm,Power,Horn/Piezo Test
Operating Temperature+32 deg F to +120 deg F (0 deg C to +49 deg C)
Alarm ContactsTwo sets of Form C contacts rated for 10 A at 250 VAC
Current ConsumptionActive 55 mA,Standby 10 mA

The FAD325R Analog Duct Detector with Relays is an accessory device. It comes with a FAD325DH Analog Duct Smoke Detector Replacement and housing for use in heating, ventilation, and air conditioning (HVAC) systems.

Features:
  • Detects and limits the spread of smoke throughout
  • building HVAC ducts
  • Comes with FAD???325???DH Analog Duct Smoke
  • Detector Replacement
  • Provides two sets of Form C alarm contacts
  • Easy to install with a drill template
  • Steel sampling tube - no screens or filters to clean
Request
Callback
Yes! I am Interested

D-296 Beam Detector

D-296 Beam Detector
  • D-296 Beam Detector
Get Best Quote
Approx. Price: Rs 31,000 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
BrandBosch
Model NumberD-296
Relative Humidity0% to 95%,non-condensing
Dimensions7 in. x 5.5 in. x 5.5 in. (17.8 cm x 14 cm x 14 cm)
Alarm Current70 mA maximum at 24 VDC
Standby CurrentReceiver 45 mA at 24 VDC Transmitter 20 mA at 24 VDC
Operating Voltage18.0 VDC to 32.0 VDC
Operating Temperature-22 deg F to +130 deg F (-30 deg C to +54 deg C)
Storage Temperature+32 deg F to +130 deg F (0 deg C to +54 deg C)

The D296 Long-range beam smoke detector (24V) is used in clear open structures. Arenas, atriums, auditoriums, ballrooms, churches, factories, museums, and warehouses are typical areas. Each detector consists of a transmitter, a receiver, and a remote indicator plate. The transmitter and receiver typically mount on the ceiling or high on walls or columns. They provide an effective and unobtrusive means of supervising public areas for fire protection. The remote indicator plate, included with the detector, provides a convenient means of verifying detector status. Install it anywhere within 500 ft. (152 m) of the beam receiver using 18 AWG (ISO 0.75 mm2) wire. Three LEDs indicate normal, trouble, and alarm conditions, and test points monitor the detector circuit.

Features:

Operates over distances between 30 ft (9 m) and350 ft (107 m)

Six levels of switch-selectable sensitivity

Built-in alignment sights and tamper protection

Automatic range adjustment, signal synchronization, and contamination adjustment

Remote indicator plate annunciates detector status and provides test points for voltage monitoring

Request
Callback
Yes! I am Interested

FLM-325-I4-A Contact Monitors Module

FLM-325-I4-A Contact Monitors Module
  • FLM-325-I4-A Contact Monitors Module
Get Best Quote
Approx. Price: Rs 3,500 / PieceGet Latest Price
Product Brochure

Product Details:

ModelFLM-325-I4-A
BrandBosch
Resistance End of Line Device Initiating Device Circuit10 k, 0.25 W per resistor Less than 50
Input Voltage25.3 VDC to 39 VDC
Current Nominal Maximum0.63 mA, 6.3 mA
Operating Temperature+32 deg F to +120 deg F (0 deg C to +49 deg C)
Dimensions4.7 in. x 4.2 in. x 1.4 in. (11.9 cm x 10.7 cm x 3.6 cm)
Relative HumidityUp to 90 %, non-condensing
Weight20 oz. (567 g)

The FLM-325-I4-A and FLM-325-I4-AI modules are used to connect standard Normally Open normally Closed dry contact types of fire alarm devices such as pull stations or water flow devices. The modules are mounted to a cover plate for a4¿¿¿inch square or double¿¿¿gang electrical back box. A bi-colored LED provides the module status.

Features:
  • Monitors Normally Open (NO) or normally closed (NC) contacts
  • Monitored Normally Closed (NC) contacts can be configured with or without EOL resistor
  • Module address programming with the D5070Analog Device Programmer
  • Bi¿¿¿colored LED provides module status
  • Digital data communications and power over the atwo¿¿¿wire circuit
Request
Callback
Yes! I am Interested

FPA-1000-V2 Fire Panel

FPA-1000-V2 Fire Panel
  • FPA-1000-V2 Fire Panel
Get Best Quote
Approx. Price: Rs 68,000 / PieceGet Latest Price

Product Details:

BrandBOSCH
CapacitiesMaximum 40 Ahin cabinet 7 Ah to 18 Ahin additional battery box 24 Ah to 40 Ah
Model NumberFPA-1000-V2
Current120 VAC 2 A maximum240 VAC 1 A maximum
Voltage120 VAC,60 Hz or 240 VAC,50 Hz
Fuses15 A,blade type

Features:
  • Support for up to 508 points on two analog addressable loops
  • Built-in Ethernet connector for web-browser based programming and Conettix Alarm-over-IP communication
  • Two onboard NICs and dual-line PSTN DACT
  • Peer-to-peer networking of up to eight -V2 panels in a single group
  • Suited to a wide range of applications and compatible with the latest Bosch solutions - including 440 Series Multi-criteria detectors
  • Simple system management and free online training

Request
Callback
Yes! I am Interested

FMM-325A Analog Manual Station

FMM-325A Analog Manual Station
  • FMM-325A Analog Manual Station
Get Best Quote
Approx. Price: Rs 4,500 / PieceGet Latest Price
Product Brochure

Product Details:

BrandBosch
MaterialPainted die-cast metal
Input Voltage24 VDC nominal
Activation Force5 lb (2.3 kg)
Operating Temperature+14 deg F to +120 deg F (-10 deg C to +49 deg C)
Dimensions4.75 in x 3.2 in x 0.875 in (12.1 cm x 8.1 cm x 2.2 cm)
Model NumberFMM-325A
Alarm28 mA
Standby0.35 mA typical
Polling22 mA +-20%

These manual stations are used in the polling circuit of the Bosch Security Systems, Inc.'s FPA¿¿¿1000 AnalogAddressable Fire Panels, and the D9024, D8024, andD10024A Fire Alarm Control Panels (FACP). They communicate with the control panel (both power and data) over a two¿¿¿wire polling circuit. The manual station's address on the polling circuit is set by programming an EEPROM microchip. TheD5070 Analog Device Programmer is required to set the address. All commercial buildings use manual stations. These manual stations allow people evacuating a building to initiate an alarm. The FACP identifies the alarm point on the polling circuit and the alarm lever latches in the pulled position.

Features:
  • Digital data communications and power provided over the two-wire circuit
  • EEPROM addressing in the module unit
  • Rugged die¿¿¿cast housing and corrosion resistant construction
  • Single¿¿¿gang mounting
  • Latching alarm lever
Request
Callback
Yes! I am Interested

D5070 Analog Point Programmer

D5070 Analog Point Programmer
  • D5070 Analog Point Programmer
Get Best Quote
Approx. Price: Rs 35,000 / PieceGet Latest Price
Product Brochure

Product Details:

ModelD-5070
Display TypeAnalog
ColorWhite
BrandBosch
Battery Life VoltageGood for approximately 8000 address settings 9 VDC
Weight5.4 oz (154.2 g)
Dimensions6.25 in. 4 in. x 1.3 in. (15.9 cm x 10.2 cm x 3.3 cm)

The D5070 Analog Device Programmer is a hand¿¿¿helddevice used to program address settings onEEPROM¿¿¿programmable analog devices. The programme consists of a base for detector head programming and three programming adapters for programming other modules and devices.

Features:
  • Compact and easy to use
  • Works on both detectors and modules
  • Provides address setting and reading
  • Displays the analog value
  • Programs over 8000 address settings from one battery
Request
Callback
Yes! I am Interested

FLM-325-CZM4 Conventional Zone Module

FLM-325-CZM4 Conventional Zone Module
  • FLM-325-CZM4 Conventional Zone Module
Get Best Quote
Approx. Price: Rs 3,700 / PieceGet Latest Price
Product Brochure

Product Details:

Model NumberFLM-325-CZM4
Relative Humidity90 %,non-condensing
BrandBosch
Operating Voltage17 VDC to 41 VDC
Operating Temperature+32 deg F to +120 deg F (0 deg C to +49 deg C)
Dimensions4.7 in. x 4.2 in. x 1.4 in. (11.9 cm x 10.7 cm x 3.6 cm)
Standby0.4 mA
Bicolored LEDRed and green
Active60 mA
Data Transmission22 mA +-20 %

The FLM¿¿¿325¿¿¿CZM4 Conventional Zone Module enables the FPA¿¿¿1000 Analog Addressable Fire Panels interface and monitor up to 25 conventional devices depending on the device type such as two-wire smoke detectors or pull stations. The module requires an auxiliary input voltage to provide power for the detector zone. It supervises the power supply as well as the entire zone of devices. Status conditions are reported as normal, open or short. The module offers fixed threshold levels for open and short that can not be changed. It fits into a standard4¿¿¿inch square or double¿¿¿gang electrical back box.

Features:
  • Provides a zone of up to 25 conventional smoke detectors (depending on detector type)
  • Supervises auxiliary power supply for conventional detectors
  • Compatible with Class B (Style B) or Class A(Style D)
  • Module address programming with the D5070Analog Device Programmer between 1 and 127
  • Bi¿¿¿colored LED provides module status
Request
Callback
Yes! I am Interested

FLM-325-ISO Short Circuit Isolator

FLM-325-ISO Short Circuit Isolator
  • FLM-325-ISO Short Circuit Isolator
Get Best Quote
Approx. Price: Rs 2,600 / PieceGet Latest Price
Product Brochure

Product Details:

Model NumberFLM-325-ISO
BrandBosch
Maximum Number Per Loop127
Operating Temperature+32 deg F to +120 deg F (0 deg C to +49 deg C)
Relative Humidity90 %, non-condensing
Input Voltage17 VDC to 41 VDC
Dimension4.7 in. x 4.2 in. x 1.4 in. (11.9 cm x 10.7 cm x 3.6 cm)
Weight1.4 oz (39.7 g)
Current ConsumptionStandby 0.27 mA, Active (LED on) 10 mA
LED indicationYellow

The FLM¿¿¿325¿¿¿ISO Short Circuit Isolator isolates shorted section on a specific polling circuit from the rest of the system to minimize the loss of devices. It fits into a standard 4-inch square or double¿¿¿gangelectrical back box.

Features:
  • Automatic verification of data line for short circuit
  • Contacts are rated to 1 A at 30 VDC
  • Can be placed at any location on SLC loop
  • 256 devices at maximum per loop for Class A(Style 7)
  • Yellow LED provides data line status
Request
Callback
Yes! I am Interested

FLM-325-2R4-A Dual Relay Modules

FLM-325-2R4-A Dual Relay Modules
  • FLM-325-2R4-A Dual Relay Modules
Get Best Quote
Approx. Price: Rs 4,200 / PieceGet Latest Price
Product Brochure

Product Details:

Model NumberFLM-325-2R4-A
BrandBosch
ContactsTwo Form C
Current ConsumptionSLC 0.405 mA,SCI Isolation 10 mA typical
Dimensions4.7 in. x 4.2 in. x 0.85 in. (11.9 cm x 10.7 cm x 2.16 cm)
Bicolored LEDRed and green
Operarting Voltage24 VDC to 39 VDC
Relative HumidityUp to 90%,non-condensing
SLC Applied25.5 VDC to 39 VDC
Operating Temperature+32 deg F to +120 deg F (0 deg C to 49 deg C)

The modules provide two independently controlledForm C contacts while utilizing only one address point the Signaling Line Circuit (SLC). The two Form Contacts can be used for a variety of Normally Open and Normally Closed applications such as fan, elevator and door control, or auxiliary notification. As the modules use mechanically latching relays, separate 24 VDC power supply is not required. They fit into a standard 4¿¿¿inch square or double¿¿¿gangelectrical back box.

Features:
  • Two independently configurable Form C contacts
  • Contacts are rated 1 A at 30 VDC or 0.5 Aat 125 VAC
  • Module address programming with the D5070Analog Device Programmer
  • Bi¿¿¿colored LED provides module status
  • Digital data communications and power over the a two¿¿¿wire circuit
Request
Callback
Yes! I am Interested

W-HSR Fire Alarm Wall Strobe

W-HSR Fire Alarm Wall Strobe
  • W-HSR Fire Alarm Wall Strobe
Get Best Quote
Approx. Price: Rs 4,750 / PieceGet Latest Price

Product Details:

Volume Settings90 db, 95 db, or 99 db
Temperature+32 deg F to +120 deg F (0 deg C to +49 deg C)
BrandBosch
Relative Humidity93+-2% maximum, non-condensing
Voltage12/24V
Model NumberW-HSR
Dimensions5.24 in. x 4.58 in. x 2.19 in. (133.1 mm x 116.4 mm x 55.7 mm)
MaterialMolded plastic enclosure incorporating a Xenon flashtube and Lexan lens.

Features:
  • Sleek modern aesthetics
  • Multiple voltages (12 VDC or 24 VDC)
  • Voltage test points
  • Eight strobe candela options and three horn volume options
  • Universal mounting base
  • Environment???friendly low current draw

Request
Callback
Yes! I am Interested

FPE-1000-SLC Signaling Line Circuit

FPE-1000-SLC Signaling Line Circuit
  • FPE-1000-SLC Signaling Line Circuit
Get Best Quote
Approx. Price: Rs 15,000 / PieceGet Latest Price
Product Brochure

Product Details:

BrandBOSCH
Operating Temperature+32 deg F to +120 deg F (0 deg C to +49 deg C)
Circuit Inductance1 mH
Wire Gauge12 AWG to 18 AWG (ISO 4 mm 2 to 0.75 mm 2 )
Environment FriendlyRoHS compliant
Circuit Resistance50
Circuit Capacitance1 uF
Relative HumidityUp to 95%,non-condensing
Storage Temperature-4 deg F to +140 deg F (-20 deg C to +60 deg C)
Line VoltageNominal 39 VDC,Range 29 VDC to 40 VDC)
Line Current204 mA (per FPE-1000-SLC)

The FPE???1000???SLC Signaling Line Circuit Plug???inModule provides a Signaling Line Circuit (SLC) for connection of analog devices to the FPA???1000 AnalogAddressable Fire Panels. It is mandatory equipment which installs at the top position on the main board in the fire panel. A second FPE-1000-SLC Plug-in Module can be installed as an option in the position below the first SLC board. The bottom position can be equipped with an optional FPE???1000???CITY City Tie Plug???inModule. The plug???in modules connect directly to the main board. Signaling Line Circuits can be wired as Class A Style 6or 7 or Class B Style 4 circuits. Class A configuration is recommended because this allows the system to poll the circuit in both directions, ensuring circuit operation in the event of a single break in the wiring. Each SLC is power???limited and supervised.

Features:
  • Signaling Line Circuit (SLC) is power-limited and supervised
  • Configurable as one Class A Style 6 or 7 or two class B Style 4 circuits
  • Up to 254 detectors and modules, or 127 analog sounder bases in combination with suitable detectors
Request
Callback
Yes! I am Interested

W-HNR Two Wire Wall Mount Horn

W-HNR Two Wire Wall Mount Horn
  • W-HNR Two Wire Wall Mount Horn
Get Best Quote
Approx. Price: Rs 2,800 / PieceGet Latest Price
Product Brochure

Product Details:

MaterialMolded plastic enclosure
Model NoW-HN
Voltage12 / 24 V
BrandBosch
Volume Setting90 db,95 db,or 99 db
Relative Humidity93+-2% maximum,non-condensing
Operating Temperature+32 deg F to +120 deg F (0 deg C to +49 deg C)
Dimensions5.24 in x 4.58 in x 1.6 in (133.1 mm x 116.4 mm x 40.7 mm)

The Cooper Wheelock Exceder Series Horns feature a sleek modern design that incorporates high reliability to minimize current draw. The reduced current draw allows for a greater number of devices on the two‑wire notification appliance circuit. This, in combination with no tools needed for changing settings, voltage test points, 12 V or 24 V DC operation, the universal mounting base, and multiple mounting options results in a reduced cost of ownership. These horns provide three sound settings on each
appliance. All the switches to change these settings can be set without a tool and are located behind the appliance to prevent tampering. The separate universal mounting base can be easily
mounted to five industry‑standard back box types. They can also be pre‑wired to allow full testing of the circuit wiring before the appliance is installed and the surface finished. These wall‑mounting horns also feature voltage test points for taking readings with a
volt meter for troubleshooting or AHJ inspection.

Features:
  • Sleek modern aesthetics
  • Multiple voltages (12 VDC or 24 VDC)
  • Voltage test points
  • Three horn volume options
  • Universal mounting base
Request
Callback
Yes! I am Interested

FAA-440-B4 Analog Base 4 Inch

FAA-440-B4 Analog Base 4 Inch
  • FAA-440-B4 Analog Base 4 Inch
Get Best Quote
Approx. Price: Rs 220 / PieceGet Latest Price
Product Brochure

Product Details:

Dimensions4.4 in. x 2.0 in. (11.2 cm x 5.1 cm)
Model NumberFAA-440-B4
BrandBosch
Relative humidity95%
Operating Voltage24 V DC to 41 V DC
Protection CategoryIP42
Standby0.07 mA
Alarm10 mA
Installation Temperature+32 deg F to +100 deg F (0 deg C to +38 deg C)

The FAA‑440 Analog Bases come in two sizes (4 in.[10 cm] and 6 in. [16 cm]) and two models (Standard and ISO which has a built‑in isolator). They are used in combination with FAP-440 and FAH-440 analog addressable detectors to provide early fire warning for life safety and property protection.

Features:
  • Modular design
  • Easy detector removal for cleaning and servicing
  • Stable mounting of detectors
  • Terminal screws for remote LED, Data In, and Out provided
  • Some models include isolator circuitry which prevents the entire SLC loop from being disabled when a short circuit occurs
Request
Callback
Yes! I am Interested

FMR-1000-RCMD Remote Command Center

FMR-1000-RCMD Remote Command Center
  • FMR-1000-RCMD Remote Command Center
Get Best Quote
Approx. Price: Rs 29,500 / PieceGet Latest Price
Product Brochure

Product Details:

MaterialABS-FR
Dimensions7.40 in x 4.41 in x 1.89 in. (188 mm x 112 mm x 48 mm)
Model NumberFMR-1000-RCMD
Storage Temperature-4 deg F to +140 deg F (-20 deg C to +60 deg C)
Operating Voltage12 VDC or 24 VDC nominal
Protection ClassIP 30 per IEC 605029
Relative HumidityUp to 95%,non-condensing
Operating Temperature+32 deg F to +120 deg F (0 deg C to +49 deg C)
BrandBosch
Weight15.2 oz (430 g)

The FMR‑1000‑RCMD Remote Command Center is a four-conductor LCD annunciator with system control capability for use with FCP‑1000 Analog AddressableFire Panels. It shows the equivalent LEDs and LCD display and includes a piezo sounder, navigation buttons, and operation keys for drill, reset, silence, and acknowledge. The navigation functions and acknowledge key are accessible without restriction—even when wearing fireman gloves. The keys for reset, silence or drill can be enabled and disabled by the device key lock, or the key lock can be disabled to provide full access to the controls.

Features:
  • LED status indicators
  • 80‑character LCD display
  • Piezo Sounder
  • Navigation buttons
  • Operations keys for drill, reset, silence, and acknowledge
Request
Callback
Yes! I am Interested

Bosch Fire Alarm Systems

Bosch Fire Alarm Systems
    Get Best Quote
    Approx. Price: Rs 68,000 / PieceGet Latest Price
    We are the reputed Authorized Wholesale Dealer and Exporter of a wide range of Bosch IP Bullet CCTV Camera, Bosch IP Dome CCTV Camera
    Request
    Callback
    Get Best Quote
    Yes! I am Interested

    EST Smoke Detectors

    EST Smoke Detectors
      Get Best Quote
      Approx. Price: Rs 10,200 / PieceGet Latest Price
      Nadvin Techlabs is one of the prominent Authorized Wholesale Dealer, Exporter of a wide range of Bosch IP Bullet CCTV Camera, Bosch IP Dome CCTV Camera, Bosch IP PTZ CCTV Camera, Bosch IP BOX CCTV Camera, Bosch CCTV Camera Accessories, Bosch Conference System, Bosch Speakers, Bosch Voice Alarm System, Bosch Addressable Fire Alarm-UL and many more.
      Request
      Callback
      Get Best Quote
      Yes! I am Interested
      X

      Product Videos

      Watch More Videos

      Explore More Products

      View All Products




      Reach Us
      Aditya Agrawal (Partner)
      Nadvin Techlabs
      No. 60, Park City
      Raigarh - 496001, Chhattisgarh, India


      Call Us